首页     开始     To Survive in the Universe    
Inhabited Sky
    News@Sky     天文图片     收集     论坛     Blog New!     常见问题     新闻     登录  

αβ Cap (???)


目录

图像

上传图像

DSS Images   Other Images


相关文章

CHARM2: An updated Catalog of High Angular Resolution Measurements
We present an update of the Catalog of High Angular ResolutionMeasurements (CHARM, Richichi & Percheron \cite{CHARM}, A&A,386, 492), which includes results available until July 2004. CHARM2 is acompilation of direct measurements by high angular resolution methods,as well as indirect estimates of stellar diameters. Its main goal is toprovide a reference list of sources which can be used for calibrationand verification observations with long-baseline optical and near-IRinterferometers. Single and binary stars are included, as are complexobjects from circumstellar shells to extragalactic sources. The presentupdate provides an increase of almost a factor of two over the previousedition. Additionally, it includes several corrections and improvements,as well as a cross-check with the valuable public release observationsof the ESO Very Large Telescope Interferometer (VLTI). A total of 8231entries for 3238 unique sources are now present in CHARM2. Thisrepresents an increase of a factor of 3.4 and 2.0, respectively, overthe contents of the previous version of CHARM.The catalog is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/431/773

Determination of fundamental characteristics for stars of the F, G, and K spectral types. The surface gravities and metallicity parameters.
Not Available

Empirically Constrained Color-Temperature Relations. II. uvby
A new grid of theoretical color indices for the Strömgren uvbyphotometric system has been derived from MARCS model atmospheres and SSGsynthetic spectra for cool dwarf and giant stars having-3.0<=[Fe/H]<=+0.5 and 3000<=Teff<=8000 K. Atwarmer temperatures (i.e., 8000-2.0. To overcome thisproblem, the theoretical indices at intermediate and high metallicitieshave been corrected using a set of color calibrations based on fieldstars having well-determined distances from Hipparcos, accurateTeff estimates from the infrared flux method, andspectroscopic [Fe/H] values. In contrast with Paper I, star clustersplayed only a minor role in this analysis in that they provided asupplementary constraint on the color corrections for cool dwarf starswith Teff<=5500 K. They were mainly used to test thecolor-Teff relations and, encouragingly, isochrones thatemploy the transformations derived in this study are able to reproducethe observed CMDs (involving u-v, v-b, and b-y colors) for a number ofopen and globular clusters (including M67, the Hyades, and 47 Tuc)rather well. Moreover, our interpretations of such data are verysimilar, if not identical, with those given in Paper I from aconsideration of BV(RI)C observations for the sameclusters-which provides a compelling argument in support of thecolor-Teff relations that are reported in both studies. Inthe present investigation, we have also analyzed the observedStrömgren photometry for the classic Population II subdwarfs,compared our ``final'' (b-y)-Teff relationship with thosederived empirically in a number of recent studies and examined in somedetail the dependence of the m1 index on [Fe/H].Based, in part, on observations made with the Nordic Optical Telescope,operated jointly on the island of La Palma by Denmark, Finland, Iceland,Norway, and Sweden, in the Spanish Observatorio del Roque de losMuchachos of the Instituto de Astrofisica de Canarias.Based, in part, on observations obtained with the Danish 1.54 mtelescope at the European Southern Observatory, La Silla, Chile.

Survey of long-term variability of stars. I. Reliability of magnitudes in old star catalogues
The comparison of visual magnitudes of stars compiled in old cataloguesis expected to yield information about their long-term magnitudevariations. In seven old catalogues whose historical data have beenintensively compared, 2123 sampled stars have been studied, disregardingstars that we could not identify, double stars which could bemisidentified, or stars observed under poor conditions, and knownvariable stars with large amplitude discrepancies. The independence ofstellar magnitude catalogues is demonstrated by comparing seven oldstudies to each other, suggesting that the magnitude estimates in eachcatalogue reflect the brightness at each observational period.Furthermore, by comparing them with a modern star catalogue, themagnitude differences show a Gaussian distribution. Therefore, if theyare sufficiently larger than the deduced standard deviations, themagnitude variations between the catalogues can be considered real.Thus, the stellar magnitudes compiled in old studies can be used asscientific data within the average intrinsic uncertainty. These sevenold catalogues can be used as data for the survey of the long-termvariability of stars.

CHARM: A Catalog of High Angular Resolution Measurements
The Catalog of High Angular Resolution Measurements (CHARM) includesmost of the measurements obtained by the techniques of lunaroccultations and long-baseline interferometry at visual and infraredwavelengths, which have appeared in the literature or have otherwisebeen made public until mid-2001. A total of 2432 measurements of 1625sources are included, along with extensive auxiliary information. Inparticular, visual and infrared photometry is included for almost allthe sources. This has been partly extracted from currently availablecatalogs, and partly obtained specifically for CHARM. The main aim is toprovide a compilation of sources which could be used as calibrators orfor science verification purposes by the new generation of largeground-based facilities such as the ESO Very Large Interferometer andthe Keck Interferometer. The Catalog is available in electronic form atthe CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/386/492, and from theauthors on CD-Rom.

Catalogue of Apparent Diameters and Absolute Radii of Stars (CADARS) - Third edition - Comments and statistics
The Catalogue, available at the Centre de Données Stellaires deStrasbourg, consists of 13 573 records concerning the results obtainedfrom different methods for 7778 stars, reported in the literature. Thefollowing data are listed for each star: identifications, apparentmagnitude, spectral type, apparent diameter in arcsec, absolute radiusin solar units, method of determination, reference, remarks. Commentsand statistics obtained from CADARS are given. The Catalogue isavailable in electronic form at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcar?J/A+A/367/521

Dark-speckle coronagraphic detection of binary stars in the near-IR
In this paper, we present the first attempt to obtain images of binarystars in the near IR using the dark-speckle method on the 3.6 mtelescope at La Silla. Promising results are presented, despite theeffect of the detector high read-out noise affecting the efficiency ofspeckle observations. We give some comparisons with the long exposuremethod. We derive in these data a reliable limit of detection for binarystar companions, around mK<4 stars, which is about<~ mK~ 6-7 for angular separations ranging from 0.5'' to0.9''. Based on observations collected at the European SouthernObservatory, La Silla, Chile.

Research Note Hipparcos photometry: The least variable stars
The data known as the Hipparcos Photometry obtained with the Hipparcossatellite have been investigated to find those stars which are leastvariable. Such stars are excellent candidates to serve as standards forphotometric systems. Their spectral types suggest in which parts of theHR diagrams stars are most constant. In some cases these values stronglyindicate that previous ground based studies claiming photometricvariability are incorrect or that the level of stellar activity haschanged. Table 2 is only available in electronic form at the CDS viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/367/297

The proper motions of fundamental stars. I. 1535 stars from the Basic FK5
A direct combination of the positions given in the HIPPARCOS cataloguewith astrometric ground-based catalogues having epochs later than 1939allows us to obtain new proper motions for the 1535 stars of the BasicFK5. The results are presented as the catalogue Proper Motions ofFundamental Stars (PMFS), Part I. The median precision of the propermotions is 0.5 mas/year for mu alpha cos delta and 0.7mas/year for mu delta . The non-linear motions of thephotocentres of a few hundred astrometric binaries are separated intotheir linear and elliptic motions. Since the PMFS proper motions do notinclude the information given by the proper motions from othercatalogues (HIPPARCOS, FK5, FK6, etc.) this catalogue can be used as anindependent source of the proper motions of the fundamental stars.Catalogue (Table 3) is only available at the CDS via anonymous ftp tocdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strastg.fr/cgi-bin/qcat?J/A+A/365/222

K-Band Calibration of the Red Clump Luminosity
The average near-infrared (K-band) luminosity of 238 Hipparcos red clumpgiants is derived and then used to measure the distance to the Galacticcenter. These Hipparcos red clump giants have been previously employedas I-band standard candles. The advantage of the K-band is a decreasedsensitivity to reddening and perhaps a reduced systematic dependence onmetallicity. In order to investigate the latter, and also to refer ourcalibration to a known metallicity zero point, we restrict our sample ofred clump calibrators to those with abundances derived fromhigh-resolution spectroscopic data. The mean metallicity of the sampleis [Fe/H]=-0.18 dex (σ=0.17 dex). The data are consistent with nocorrelation between MK and [Fe/H] and only weakly constrainthe slope of this relation. The luminosity function of the sample peaksat MK=-1.61+/-0.03 mag. Next, we assemble published opticaland near-infrared photometry for ~20 red clump giants in a Baade'swindow field with a mean metallicity of [Fe/H]=-0.17+/-0.09 dex, whichis nearly identical to that of the Hipparcos red clump. Assuming thatthe average (V-I)0 and (V-K)0 colors of these twored clumps are the same, the extinctions in the Baade's window field arefound to be AV=1.56, AI=0.87, andAK=0.15, in agreement with previous estimates. We derive thedistance to the Galactic center: (m-M)0=14.58+/-0.11 mag, orR=8.24+/-0.42 kpc. The uncertainty in this distance measurement isdominated by the small number of Baade's window red clump giantsexamined here.

Determination of the characteristics of stars of spectral types F,G,K. The effective temperatures.
Not Available

Spectral Irradiance Calibration in the Infrared. X. A Self-Consistent Radiometric All-Sky Network of Absolutely Calibrated Stellar Spectra
We start from our six absolutely calibrated continuous stellar spectrafrom 1.2 to 35 μm for K0, K1.5, K3, K5, and M0 giants. These wereconstructed as far as possible from actual observed spectral fragmentstaken from the ground, the Kuiper Airborne Observatory, and the IRAS LowResolution Spectrometer, and all have a common calibration pedigree.From these we spawn 422 calibrated ``spectral templates'' for stars withspectral types in the ranges G9.5-K3.5 III and K4.5-M0.5 III. Wenormalize each template by photometry for the individual stars usingpublished and/or newly secured near- and mid-infrared photometryobtained through fully characterized, absolutely calibrated,combinations of filter passband, detector radiance response, and meanterrestrial atmospheric transmission. These templates continue ourongoing effort to provide an all-sky network of absolutely calibrated,spectrally continuous, stellar standards for general infrared usage, allwith a common, traceable calibration heritage. The wavelength coverageis ideal for calibration of many existing and proposed ground-based,airborne, and satellite sensors, particularly low- tomoderate-resolution spectrometers. We analyze the statistics of probableuncertainties, in the normalization of these templates to actualphotometry, that quantify the confidence with which we can assert thatthese templates truly represent the individual stars. Each calibratedtemplate provides an angular diameter for that star. These radiometricangular diameters compare very favorably with those directly observedacross the range from 1.6 to 21 mas.

The effective temperature scale of giant stars (F0-K5). I. The effective temperature determination by means of the IRFM
We have applied the InfraRed Flux Method (IRFM) to a sample ofapproximately 500 giant stars in order to derive their effectivetemperatures with an internal mean accuracy of about 1.5% and a maximumuncertainty in the zero point of the order of 0.9%. For the applicationof the IRFM, we have used a homogeneous grid of theoretical modelatmosphere flux distributions developed by \cite[Kurucz (1993)]{K93}.The atmospheric parameters of the stars roughly cover the ranges: 3500 K<= T_eff <= 8000 K; -3.0 <= [Fe/H] <= +0.5; 0.5 <= log(g) <= 3.5. The monochromatic infrared fluxes at the continuum arebased on recent photometry with errors that satisfy the accuracyrequirements of the work. We have derived the bolometric correction ofgiant stars by using a new calibration which takes the effect ofmetallicity into account. Direct spectroscopic determinations ofmetallicity have been adopted where available, although estimates basedon photometric calibrations have been considered for some stars lackingspectroscopic ones. The adopted infrared absolute flux calibration,based on direct optical measurements of stellar angular diameters, putsthe effective temperatures determined in this work in the same scale asthose obtained by direct methods. We have derived up to fourtemperatures, TJ, TH, TK and T_{L'},for each star using the monochromatic fluxes at different infraredwavelengths in the photometric bands J, H, K and L'. They show goodconsistency over 4000 K, and there is no appreciable trend withwavelength, metallicity and/or temperature. We provide a detaileddescription of the steps followed for the application of the IRFM, aswell as the sources of error and their effect on final temperatures. Wealso provide a comparison of the results with previous work.

Catalogs of temperatures and [Fe/H] averages for evolved G and K stars
A catalog of mean values of [Fe/H] for evolved G and K stars isdescribed. The zero point for the catalog entries has been establishedby using differential analyses. Literature sources for those entries areincluded in the catalog. The mean values are given with rms errors andnumbers of degrees of freedom, and a simple example of the use of thesestatistical data is given. For a number of the stars with entries in thecatalog, temperatures have been determined. A separate catalogcontaining those data is briefly described. Catalog only available atthe CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/Abstract.html

Averaged energy distributions in the stellar spectra.
Not Available

Broad-band JHK(L') photometry of a sample of giants with 0.5 > [Fe/H] > -3
We present the results of a three-year campaign of broad-band photometryin the near-infrared J, H, K and L' bands for a sample of approximately250 giant stars carried out at the Observatorio del Teide (Tenerife,Spain). Transformations of the Telescopio Carlos Sanchez systeminto/from several currently used infrared systems are extended to theredward part of the colour axis. The linearity of our photometric systemin the range -3 mag [Fe/H] >-3. Data of comparable quality previouslypublished have been added to the sample in order to increase thereliability of the relations to be obtained. We also provide mean IRcolours for giant stars according to spectral type.ables 1, 2 and 3 are only available in electronic form via the CDS(anonymous ftp 130.79.128.5 or http://cdsweb.u-strasbg.fr/Abstract.html

Determination of the temperatures of selected ISO flux calibration stars using the Infrared Flux Method
Effective temperatures for 420 stars with spectral types between A0 andK3, and luminosity classes between II and V, selected for a fluxcalibration of the Infrared Space Observatory, ISO, have been determinedusing the Infrared Flux Method (IRFM). The determinations are based onnarrow and wide band photometric data obtained for this purpose, andtake into account previously published narrow-band measures oftemperature. Regression coefficients are given for relations between thedetermined temperatures and the photometric parameters (B2-V1), (b-y)and (B-V), corrected for interstellar extinction through use ofHipparcos parallaxes. A correction for the effect of metallicity on thedetermination of integrated flux is proposed. The importance of aknowledge of metallicity in the representation of derived temperaturesfor Class V, IV and III stars by empirical functions is discussed andformulae given. An estimate is given for the probable error of eachtemperature determination. Based on data from the ESA HipparcosAstrometry Satellite.

The ROSAT all-sky survey catalogue of optically bright late-type giants and supergiants
We present X-ray data for all late-type (A, F, G, K, M) giants andsupergiants (luminosity classes I to III-IV) listed in the Bright StarCatalogue that have been detected in the ROSAT all-sky survey.Altogether, our catalogue contains 450 entries of X-ray emitting evolvedlate-type stars, which corresponds to an average detection rate of about11.7 percent. The selection of the sample stars, the data analysis, thecriteria for an accepted match between star and X-ray source, and thedetermination of X-ray fluxes are described. Catalogue only available atCDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or viahttp://cdsweb.u-strasbg.fr/Abstract.html

Towards a fundamental calibration of stellar parameters of A, F, G, K dwarfs and giants
I report on the implementation of the empirical surface brightnesstechnique using the near-infrared Johnson broadband { (V-K)} colour assuitable sampling observable aimed at providing accurate effectivetemperatures of 537 dwarfs and giants of A-F-G-K spectral-type selectedfor a flux calibration of the Infrared Space Observatory (ISO). Thesurface brightness-colour correlation is carefully calibrated using aset of high-precision angular diameters measured by moderninterferometry techniques. The stellar sizes predicted by thiscorrelation are then combined with the bolometric flux measurementsavailable for a subset of 327 ISO standard stars in order to determineone-dimensional { (T, V-K)} temperature scales of dwarfs and giants. Theresulting very tight relationships show an intrinsic scatter induced byobservational photometry and bolometric flux measurements well below thetarget accuracy of +/- 1 % required for temperature determinations ofthe ISO standards. Major improvements related to the actual directcalibration are the high-precision broadband { K} magnitudes obtainedfor this purpose and the use of Hipparcos parallaxes for dereddeningphotometric data. The temperature scale of F-G-K dwarfs shows thesmallest random errors closely consistent with those affecting theobservational photometry alone, indicating a negligible contributionfrom the component due to the bolometric flux measurements despite thewide range in metallicity for these stars. A more detailed analysisusing a subset of selected dwarfs with large metallicity gradientsstrongly supports the actual bolometric fluxes as being practicallyunaffected by the metallicity of field stars, in contrast with recentresults claiming somewhat significant effects. The temperature scale ofF-G-K giants is affected by random errors much larger than those ofdwarfs, indicating that most of the relevant component of the scattercomes from the bolometric flux measurements. Since the giants have smallmetallicities, only gravity effects become likely responsible for theincreased level of scatter. The empirical stellar temperatures withsmall model-dependent corrections are compared with the semiempiricaldata by the Infrared Flux Method (IRFM) using the large sample of 327comparison stars. One major achievement is that all empirical andsemiempirical temperature estimates of F-G-K giants and dwarfs are foundto be closely consistent between each other to within +/- 1 %. However,there is also evidence for somewhat significant differential effects.These include an average systematic shift of (2.33 +/- 0.13) % affectingthe A-type stars, the semiempirical estimates being too low by thisamount, and an additional component of scatter as significant as +/- 1 %affecting all the comparison stars. The systematic effect confirms theresults from other investigations and indicates that previousdiscrepancies in applying the IRFM to A-type stars are not yet removedby using new LTE line-blanketed model atmospheres along with the updatedabsolute flux calibration, whereas the additional random component isfound to disappear in a broadband version of the IRFM using an infraredreference flux derived from wide rather than narrow band photometricdata. Table 1 and 2 are only available in the electronic form of thispaper

The Tokyo PMC catalog 90-93: Catalog of positions of 6649 stars observed in 1990 through 1993 with Tokyo photoelectric meridian circle
The sixth annual catalog of the Tokyo Photoelectric Meridian Circle(PMC) is presented for 6649 stars which were observed at least two timesin January 1990 through March 1993. The mean positions of the starsobserved are given in the catalog at the corresponding mean epochs ofobservations of individual stars. The coordinates of the catalog arebased on the FK5 system, and referred to the equinox and equator ofJ2000.0. The mean local deviations of the observed positions from theFK5 catalog positions are constructed for the basic FK5 stars to comparewith those of the Tokyo PMC Catalog 89 and preliminary Hipparcos resultsof H30.

Classification and Identification of IRAS Sources with Low-Resolution Spectra
IRAS low-resolution spectra were extracted for 11,224 IRAS sources.These spectra were classified into astrophysical classes, based on thepresence of emission and absorption features and on the shape of thecontinuum. Counterparts of these IRAS sources in existing optical andinfrared catalogs are identified, and their optical spectral types arelisted if they are known. The correlations between thephotospheric/optical and circumstellar/infrared classification arediscussed.

A catalogue of [Fe/H] determinations: 1996 edition
A fifth Edition of the Catalogue of [Fe/H] determinations is presentedherewith. It contains 5946 determinations for 3247 stars, including 751stars in 84 associations, clusters or galaxies. The literature iscomplete up to December 1995. The 700 bibliographical referencescorrespond to [Fe/H] determinations obtained from high resolutionspectroscopic observations and detailed analyses, most of them carriedout with the help of model-atmospheres. The Catalogue is made up ofthree formatted files: File 1: field stars, File 2: stars in galacticassociations and clusters, and stars in SMC, LMC, M33, File 3: numberedlist of bibliographical references The three files are only available inelectronic form at the Centre de Donnees Stellaires in Strasbourg, viaanonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5), or viahttp://cdsweb.u-strasbg.fr/Abstract.html

On the Determination of Empirical Stellar Flux Scales
Several studies have appeared in the literature describing methods forderiving stellar continuum fluxes as simple functions of Johnson colorindices. In previous papers, we have used similar relations to derive CaII H and K line core fluxes for dwarf stars on Lowell Observatory'sSolar-Stellar Spectrograph (SSS) program. Our desire is to present ourdata, and complementary data from the Mt. Wilson and National SolarObservatory stellar and solar programs, in terms of physical fluxes.However, our existing relations break down for mid-K and later stars andfor giant stars, which form an important element of our target list. Inthis work I have used a broader range of spectrophotometry and angulardiamters than in our previous work to derive empirical flux scales forspectral types A to early M, luminosity classes I to V, and for fourcolor indices, Johnson B-V, V-R, R-I, and Stromgren b-y. In this paper,I describe the methods I used and present the desired flux scales. Icompare the results with those from earlier studies and present examplesof the use of the flux scales. The data and results are available on theWorld Wide Web. (SECTION: Stars)

The Pulkovo Spectrophotometric Catalog of Bright Stars in the Range from 320 TO 1080 NM
A spectrophotometric catalog is presented, combining results of numerousobservations made by Pulkovo astronomers at different observing sites.The catalog consists of three parts: the first contains the data for 602stars in the spectral range of 320--735 nm with a resolution of 5 nm,the second one contains 285 stars in the spectral range of 500--1080 nmwith a resolution of 10 nm and the third one contains 278 stars combinedfrom the preceding catalogs in the spectral range of 320--1080 nm with aresolution of 10 nm. The data are presented in absolute energy unitsW/m(2) m, with a step of 2.5 nm and with an accuracy not lower than1.5--2.0%.

Transformations from Theoretical Hertzsprung-Russell Diagrams to Color-Magnitude Diagrams: Effective Temperatures, B-V Colors, and Bolometric Corrections
Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1996ApJ...469..355F&db_key=AST

Vitesses radiales. Catalogue WEB: Wilson Evans Batten. Subtittle: Radial velocities: The Wilson-Evans-Batten catalogue.
We give a common version of the two catalogues of Mean Radial Velocitiesby Wilson (1963) and Evans (1978) to which we have added the catalogueof spectroscopic binary systems (Batten et al. 1989). For each star,when possible, we give: 1) an acronym to enter SIMBAD (Set ofIdentifications Measurements and Bibliography for Astronomical Data) ofthe CDS (Centre de Donnees Astronomiques de Strasbourg). 2) the numberHIC of the HIPPARCOS catalogue (Turon 1992). 3) the CCDM number(Catalogue des Composantes des etoiles Doubles et Multiples) byDommanget & Nys (1994). For the cluster stars, a precise study hasbeen done, on the identificator numbers. Numerous remarks point out theproblems we have had to deal with.

Radio continuum emission from stars: a catalogue update.
An updated version of my catalogue of radio stars is presented. Somestatistics and availability are discussed.

A revised effective-temperature calibration for the DDO photometric system
A revised effective-temperature calibration for the David DunlapObservatory (DDO) photometric system is presented. Recently publishedphotometric and spectroscopic observations of field and open-cluster Gand K stars allow a better definition of the solar-abundance fiducialrelation in the DDO C0(45-48) vs. C0(42-45)diagram. The ability of the DDO system to predict MK spectral types of Gand K giants is demonstrated. The new DDO effective temperaturecalibration reproduces satisfactorily the infrared temperature scale ofBell and Gustafsson (1989). It is shown that Osborn's (1979) calibrationunderestimates the effective temperatures of K giants by approximately170 K and those of late-type dwarfs by approximately 150 K.

Near-infrared spectroscopy of proto-planetary nebulae
Sixteen proto-planetary nebulae were observed with low-resolutioninfrared spectroscopy in the H and K bands, and four were observed inthe L band. In the H band, most of the objects show hydrogen Brackettlines (from n = 10 goes to 4 to n = 20 goes to 4) in absorption. In theK band, absorption bands (delta (nu) = 2) of CO were observed to as highas nu = 6 goes to 4, and in three cases the CO bands are in emission.The CO spectrum of 22272 + 5435 was found to change from emission toabsorption over a 3 month interval. The CO emission most likely arisesfrom collisional excitation resulting from recent episodes of mass loss.One new object which possibly shows weak 3.3 micron emission was found.

Metal enrichment in elliptical galaxies and globular clusters through the study of iron and H-Beta spectral indices
Chemical evolution of elliptical galaxies and globular clusters isaddressed through a combined study of the iron indices at 5270 and 5335A, and of the H-Beta line strength. The observational database of 74standard stars (both dwarfs and giants) referred to in a previous paper(Buzzoni et al. (1992)) complemented with the data of Faber et al.(1985) and Gorgas et al. (1993) allowed us to explore here Fe and H-Betaindex dependence on stellar temperature, gravity, and metallicity. Thederived fitting functions were then included into Buzzoni's (1989) codefor population synthesis in order to derive expected integrated indicesfor simple stellar populations and compare with observations. Partitionof metals in the current chemical mix of galaxies and globulars has beenconstrained supporting the claim that light alpha elements might beenhanced in the globular cluster metal-poor population. An alternativeconclusion resting on the standard framework with (alpha/Fe) = 0 wouldrequire a systematically larger age, about 18-20 Gyr. Iron and magnesiumin ellipticals are found in average solar but a systematic trend of(Mg/Fe) vs global metallicity does exist with iron more deficient withrespect to magnesium at high Z. We conclude that this effect mightindicate that Fe abundance per unit mass in the galaxies is constant(suggesting a constant rate per unit mass of SN I events) while lightmetals supplied by SNe II should have been more effectively enrichedwith increasing galactic total mass.

提交文章


相关链接

  • - 没有找到链接 -
提交链接


下列团体成员


观测天体数据

星座:摩羯座
右阿森松:20h18m03.30s
赤纬:-12°32'41.0"
视星:3.57
距离:33.322 天文距离
右阿森松适当运动:0
赤纬适当运动:0
B-T magnitude:4.759
V-T magnitude:3.665

目录:
适当名称???
  (Edit)
Bayerαβ Cap
Flamsteed6 Cap
HD 1989HD 192947
TYCHO-2 2000TYC 5749-2530-1
USNO-A2.0USNO-A2 0750-19913578
BSC 1991HR 7754
HIPHIP 100064

→ 要求更多目录从vizier